Metal Dek Group®

Deep-Dek® 6 Cellular (Roof)

Deep-Dek® 6 Cellular is a double cell (hat) unit with the Klean Line-R™ liner panel that provides a support surface for various component roof systems. It can be used as a secondary structural member to provide for lateral force distribution to the structure’s vertical force resisting systems. The Deep- Dek® 6 Cellular product produces a smooth underside surface with subtle shadow lines for a clean finished look.

All Deep-Dek® Cellular product features offer exceptional performance:

  • Wind resistance, snow loads, seismic, etc.
  • Open, unobstructed building environments
  • Exceptional aesthetics
  • Quiet
  • Dek-Knek® Sidelap Attachment System

Deep-Dek® 6 Cellular is available in a twenty-four inch (24”) cover width. It is available in nine (9) steel gage thicknesses (see load tables), with various deck/liner panel thicknesses, a variety of galvanized coating weights and an array of paint systems all suited to specific project performance specifications.

Deep-Dek® 6 Cellular is ICC approved.

View Disclaimer

Name File Type Description
Deep-Dek 6 Cellular ASD Load Table ASD Load Table
Deep-Dek 6 Cellular LRFD Load Table LRFD Load Table
Deep-Dek® 6 Cellular Diaphragm Tables Diaphragm Tables
Deep-Dek® 6 Cellular Web Crippling Table Web Crippling Table
3 Part Specification 3 Part Specification
Name File Type Description
Deep-Dek® 6 Cellular Attachment Pattern
Name DWG PDF File Type
D6C-R-CMU-007 Deep-Dek® 6 Cellular on load bearing CMU wall: Change in Direction
D6C-R-CMU-006 Deep-Dek® 6 Cellular on load bearing CMU wall: Interior Condition
D6C-R-CMU-005 Deep-Dek® 6 Cellular on non-load bearing CMU wall: Interior Condition
D6C-R-CMU-002 Deep-Dek® 6 Cellular on load bearing CMU wall: Ridge Condition
D6C-R-CMU-001 Deep-Dek® 6 Cellular on non-load bearing CMU wall: Ridge Condition
D6C-R-CMU-008 Deep-Dek® 6 Cellular on load bearing CMU wall: End Condition
D6C-R-CMU-009 Deep-Dek® 6 Cellular on load bearing CMU wall: End Condition with Overhang
D6C-R-CON-001 Deep-Dek® 6 Cellular on non-load bearing concrete wall: Ridge Condition
D6C-R-CON-005 Deep-Dek® 6 Cellular on non-load bearing concrete wall: Interior Condition
D6C-R-CON-002 Deep-Dek® 6 Cellular on load bearing concrete wall: Ridge Condition
D6C-R-CON-007 Deep-Dek® 6 Cellular on load bearing concrete wall: Change in Direction
D6C-R-CON-006 Deep-Dek® 6 Cellular on load bearing concrete wall: Interior Condition
D6C-R-CON-008 Deep-Dek® 6 Cellular on load bearing concrete wall: End Condition
D6C-R-CON-009 Deep-Dek® 6 Cellular on load bearing concrete wall: End Condition with Overhang
D6C-R-LGS-001 Deep-Dek® 6 Cellular on light gauge steel truss: Ridge Condition
D6C-R-LGS-005 Deep-Dek® 6 Cellular on non-load bearing light gauge steel wall: Interior Condition
D6C-R-LGS-007 Deep-Dek® 6 Cellular on load bearing light gauge steel wall: Change in Direction
D6C-R-LGS-006 Deep-Dek® 6 Cellular on load bearing light gauge steel wall: Interior Condition
D6C-R-LGS-008 Deep-Dek® 6 Cellular on load bearing light gauge steel wall: End Condition
D6C-R-LGS-010 Deep-Dek® 6 Cellular on light gauge steel truss: Sloped End Condition
D6C-R-LGS-009 Deep-Dek® 6 Cellular on load bearing light gauge steel wall: End Condition with Overhang
D6C-R-P-001 Deep-Dek® 6 Cellular on roof purlins: Ridge Condition
D6C-R-RJ-001 Deep-Dek® 6 Cellular on roof joist: Ridge Condition
D6C-R-RJ-003 Deep-Dek® 6 Cellular on roof joist: Valley Condition
D6C-R-RJ-010 Deep-Dek® 6 Cellular on roof joist: Sloped End Condition
D6C-R-SA-021 Deep-Dek® 6 Cellular on structural angle: Concrete Wall
D6C-R-SA-020 Deep-Dek® 6 Cellular on structural angle: CMU Wall
D6C-R-SA-030 Deep-Dek® 6 Cellular on structural angle: CMU Wall
D6C-R-SA-022 Deep-Dek® 6 Cellular on structural angle: Light Gauge Steel Wall
D6C-R-SA-031 Deep-Dek® 6 Cellular on structural angle: Concrete Wall
D6C-R-SA-032 Deep-Dek® 6 Cellular on structural angle: Light Gauge Steel Bearing Wall
D6C-R-WF-002 Deep-Dek® 6 Cellular on wide flange beam: Ridge Condition
D6C-R-WF-004 Deep-Dek® 6 Cellular on wide flange beam: Valley Condition
D6C-R-WF-006 Deep-Dek® 6 Cellular on load bearing wide flange beam: Interior Condition
D6C-R-WF-005 Deep-Dek® 6 Cellular on non-load bearing wide flange beam: Interior Condition
D6C-R-WF-007 Deep-Dek® 6 Cellular on wide flange beam: Change in Direction
D6C-R-WF-009 Deep-Dek® 6 Cellular on wide flange beam: End Condition with Overhang
Name File Type
Butt Plates  96k
J Closures  97k
Z Closures  96k
Ridge (Hip) and Valley Plates  96k
Flat Sump Pans  98k
Flat Recessed Sump Pans  187k
Sloped Recessed Sump Pans  191k
Type 2 Tek Screws  182k
Type 3 Tek Screws  101k
Type 5 Tek Screws  106k
EC1 End Closure  96k
EC2 End Closure  96k
EC3 End Closure  96k
Finish Strips (Non-Standard) N/A
Cant Strips N/A
Neoprene/Rubber Closures (Top & Bottom End Plugs) N/A

Product Masterspec ™

Download Steel Dek Specifications

Prepare project specification documents using information from Metal Dek Group® products.

(doc file) MS Word (119k)   

Ask the Dek Design Team ®

Let Us Help

The Dek Design Team® is a full-service technical group dedicated to the engineering, design, and support of Metal Dek Group® products and services in application. More...

Bridge Dek ®

Stay in place form systems for concrete and steel bridge structures More...

a unit of CSI®
650 Rosewood Drive Columbia, SC 29201 | Tel: 800.554.5421 | Fax: 803.799.6811
© 2007 Consolidated Systems Incorporated®
Website by Cyberwoven